Products Description
The Hydromet Data Logger & Controller – Model AT3512-00 is a powerful and flexible addition to the 3306 family of transmitter products designed with the field technician in mind. It can be used as a simple data logger and in more complex control systems. The Model accepts up to 8 Analog (plus internal battery), up to 2 shaft encoders, up to 2 precipitation, SDI-12, wind speed, wind direction, and peak gust.
Additional Hydromet Data Logger & Controller features include fuse protection on the solar power input, battery and 12V switched to avoid damage to the unit through shorting (these fuses automatically reset when they cool off); and a dedicated USB port for programming, data retrieval, and uploading of new firmware versions.
You can use the included Insight software for fast, easy set-up of the Model AT3512 from either a desktop or laptop computer in the field. The AT3512 internal firmware is upgradable in the field. New firmware versions can be downloaded via the USB cable in just a few seconds.
Product Features
● 8 Analog inputs
● 5 Digital inputs, including SDI-12
● HSE Insight software app included for easy field setup and configuration
● Fuse protection on solar panel, battery, 12V switched
● 16 GB of removable memory
Product Specification
| Sensor Inputs | 8 Analog 0 to 5V, digital inputs including SDI - 12, up to 2 Up - Only Counters, up to 2 Shaft Encoders, Wind Run, ALERT Wind Format, and Peak Wind Gust |
| Total Sensors | Up to 50 |
| Analog Sensor Resolution | 12 bits (0.0012 V) |
| Output Channels | 4 digital outputs, open drain FET, active low |
| Output Channel Electrical | 750 mA max, 20 VDC max |
| Output Channel Configuration | Continuous or pulsed, 1 to 65535 second increments ret riggerable by external command |
| Local Output Channel | Up to 5 sensors associated with one or more output channels, configurable. Voting mode available, requires a majority of sensors to exceed threshold prior to activating output |
| Remote Output Channel | Status message from base station activating specified output |
| Control Inputs | - |
| Communication Protocol | 11 bit status messages, two - way command/status sequences using ALERT protocol |
| Remote Controller Management | Up to 16 remotes for each control channels (32 Max) |
| Sampling Interval | 0 seconds to 18 hrs, programmable |
| Reporting Interval | Time-defined and/or event and integration |
| Event Threshold Interval | 0 seconds to 9952.5 hrs, programmable |
| Reporting Override Value | 0 to 65535 counts |
| Holdoff Interval | 0 to 65535 counts |
| Data Logging Modes | Time - defined and/or on transmission |
| Data Logging Interval | 0 seconds to 9952.5 hrs, programmable |
| Data Format | ALERT Binary Standard |
| Recorded Data | 0 to 2047 |
| Record rate | 8 bytes/second, 1 file per month per sensor |
| Record size | 16 GB SD card, removable |
| Real Time Clock | Clock/Calendar with on - board battery back - up with leap year correction |
| Logging Memory | 0 to 8191, programmable |
| ID Number Range | 1 character |
| SDI - 12 Address | 1 character |
| Analog Sensor Warmup | 0 to 255 seconds |
| Programmable Parameter Precision | 1 digit specifying number of decimal places to convert |
| Address Programmable Parameter | IEEE 754, 32 bit float |
| Multiplier Programmable Parameter | IEEE 754, 32 bit float |
| Base Set Programmable Parameter | 0 to 65535 seconds, for Counters, Shaft Encoders, Wind Run, and ALERT Wind power |
| Shaft Encoder Parameters | Supports Quadrature format and Sierra Misco format. Supports reversing direction & pulsed or continuous |
| Live Sensor Reading | Yes, from user interface |
| Low Battery Holdoff | - |
| Programming | Included Insight Software (Windows GUI) |
| Operating Voltage | 12 VDC |
| Current Draw | - |
| Connectors | Terminal strip |
| Lightning Protection | Standard on ALL inputs. |
| Chassis | Aluminum |
| Temperature Range | -58 to 168 °F (-50 to 70 °C) |
| Operating Temperature | -40 to 160 °F (-40 to 60 °C) |
| Dimensions | 6 x 7.5 x 1 in (15.2 x 19 x 2.54 cm) |
| Weight | 0.5 lbs (227 g) |
| Shipping Weight | 1 lbs (0.5 kg) |
Product Dimensions
Product Features
● 8 Analog inputs
● 5 Digital inputs, including SDI-12
● HSE Insight software app included for easy field setup and configuration
● Fuse protection on solar panel, battery, 12V switched
● 16 GB of removable memory
Product Dimensions
Product Specification
| Sensor Inputs | 8 Analog 0 to 5V, digital inputs including SDI - 12, up to 2 Up - Only Counters, up to 2 Shaft Encoders, Wind Run, ALERT Wind Format, and Peak Wind Gust |
| Total Sensors | Up to 50 |
| Analog Sensor Resolution | 12 bits (0.0012 V) |
| Output Channels | 4 digital outputs, open drain FET, active low |
| Output Channel Electrical | 750 mA max, 20 VDC max |
| Output Channel Configuration | Continuous or pulsed, 1 to 65535 second increments ret riggerable by external command |
| Local Output Channel | Up to 5 sensors associated with one or more output channels, configurable. Voting mode available, requires a majority of sensors to exceed threshold prior to activating output |
| Remote Output Channel | Status message from base station activating specified output |
| Control Inputs | - |
| Communication Protocol | 11 bit status messages, two - way command/status sequences using ALERT protocol |
| Remote Controller Management | Up to 16 remotes for each control channels (32 Max) |
| Sampling Interval | 0 seconds to 18 hrs, programmable |
| Reporting Interval | Time-defined and/or event and integration |
| Event Threshold Interval | 0 seconds to 9952.5 hrs, programmable |
| Reporting Override Value | 0 to 65535 counts |
| Holdoff Interval | 0 to 65535 counts |
| Data Logging Modes | Time - defined and/or on transmission |
| Data Logging Interval | 0 seconds to 9952.5 hrs, programmable |
| Data Format | ALERT Binary Standard |
| Recorded Data | 0 to 2047 |
| Record rate | 8 bytes/second, 1 file per month per sensor |
| Record size | 16 GB SD card, removable |
| Real Time Clock | Clock/Calendar with on - board battery back - up with leap year correction |
| Logging Memory | 0 to 8191, programmable |
| ID Number Range | 1 character |
| SDI - 12 Address | 1 character |
| Analog Sensor Warmup | 0 to 255 seconds |
| Programmable Parameter Precision | 1 digit specifying number of decimal places to convert |
| Address Programmable Parameter | IEEE 754, 32 bit float |
| Multiplier Programmable Parameter | IEEE 754, 32 bit float |
| Base Set Programmable Parameter | 0 to 65535 seconds, for Counters, Shaft Encoders, Wind Run, and ALERT Wind power |
| Shaft Encoder Parameters | Supports Quadrature format and Sierra Misco format. Supports reversing direction & pulsed or continuous |
| Live Sensor Reading | Yes, from user interface |
| Low Battery Holdoff | - |
| Programming | Included Insight Software (Windows GUI) |
| Operating Voltage | 12 VDC |
| Current Draw | - |
| Connectors | Terminal strip |
| Lightning Protection | Standard on ALL inputs. |
| Chassis | Aluminum |
| Temperature Range | -58 to 168 °F (-50 to 70 °C) |
| Operating Temperature | -40 to 160 °F (-40 to 60 °C) |
| Dimensions | 6 x 7.5 x 1 in (15.2 x 19 x 2.54 cm) |
| Weight | 0.5 lbs (227 g) |