Clamp Connection Sanitary Pressure Sensor

Clamp Connection Sanitary Pressure Sensor

Wide measuring range;

Hygienic structure, no dead angle, anti-clogging;

Protection class IP65;

Various output signal forms, adjustable and displayed on site;

Clean flat isolation diaphragm, in line with 3A hygiene standard;

Various signal output forms, voltage, current, frequency signals, etc.;

High precision, high strength, hygienic, anti-fouling;

Send Inquiry
Products Description

 

Sanitary Pressure Sensor is a type of pressure sensing device that is specifically designed for use in sanitary environments. Such as food processing plants, pharmaceutical manufacturing facilities, and hospitals.  Clamp Connection Sanitary Pressure Sensor is equipped with a clamp connection, which allows for easy installation and maintenance without the need to disassemble the entire system.

The sensor is typically made from high-grade stainless steel and other corrosion-resistant materials to withstand the harsh conditions found in these types of environments. It is also designed to meet various industry standards, to ensure that it is safe and hygienic for use in these applications. The Clamp Connection Sanitary Pressure Sensor is an important tool for monitoring and controlling pressure levels. in sanitary environments.

Product Features

 

Wide measuring range;

Hygienic structure, no dead angle, anti-clogging;

Protection class IP65;

Various output signal forms, adjustable and displayed on site;

Reverse polarity protection and instantaneous overcurrent and overvoltage protection, in line with EMI protection requirements;

Clean flat isolation diaphragm, in line with 3A hygiene standard;

Adopt diffused silicon pressuresensor, no pressure hole, no cavity planar structure;

Various signal output forms, voltage, current, frequency signals, etc.;

High precision, high strength, hygienic, anti-fouling;

 

Product Specification

 

Item Specification
Measuring range Relative pressure: maximum 0 ~ 7MPa, minimum 0 ~ 5KPa, customized up to 100MPa
Absolute pressure: Maximum 0~60MPa; Minimum 0~20KPa
Negative relative pressure: -1KPa~-0.1MPa
Accuracy class ±0.5%F.S
Temperature effect Tk≤±0.02%FS/K
Stability Better than 0.1%FS/year
Location effect Mounting position does not affect zero point
Permissible temperature Medium temperature: -20~80℃, -40~200℃
Ambient temperature: -30~80℃
Storage temperature: -30~80℃
Protection class IP64, IP65
Adjustment range Zero adjustment range ±5%
Full scale adjustment range ±20%
Power supply 16~32VDC
Output signal 4~20mA DC (analog, two-wire system)
1~5V DC (analog, three-wire system)
Wiring lead-out method It can be drawn out from any outlet according to the needs. It is recommended to use a minimum of φ7.5 industrial cable as the lead for sealing. The lead-out connector is a general cable connector M12×1.5, and the end without the lead is sealed with an end cover
Pressure interface Stainless steel clamp type; thread M27×1.5, G1/2, G3/4, NPT1/2,

 

Product Dimensions

Order Guide

ATECH Clamp Connection Sanitary Pressure Sensor
Code Pressure Range
(0~X)KPa -100kPa…0-0.01…100MPa
Code Output Signal
B1 4-20mA
B3 0-10v
B4 0-5V
B5 1-5V
Code Process Connection
K1 2 inch clamp connection
K2 2.5 inch clamp connection
P Specify thread size
Code Electrical connections
C1 Hirschman joint
C2 Cable output
C3 Aviation connector
Code Structure Material
Diaphragm Interface Shell
M1 316L Stainless steel Stainless steel
M3 Tantalum customize customize
M4 Hastelloy C customize customize
Code Additional functions
G Gauge pressure (default)
A Absolute pressure
S Sealed gauge pressure
D1 Local display
Y2 Blue protective shell
T High temperature -XX℃


 

Product Features

 

Wide measuring range;

Hygienic structure, no dead angle, anti-clogging;

Protection class IP65;

Various output signal forms, adjustable and displayed on site;

Reverse polarity protection and instantaneous overcurrent and overvoltage protection, in line with EMI protection requirements;

Clean flat isolation diaphragm, in line with 3A hygiene standard;

Adopt diffused silicon pressuresensor, no pressure hole, no cavity planar structure;

Various signal output forms, voltage, current, frequency signals, etc.;

High precision, high strength, hygienic, anti-fouling;

 

Product Dimensions

Order Guide

ATECH Clamp Connection Sanitary Pressure Sensor
Code Pressure Range
(0~X)KPa -100kPa…0-0.01…100MPa
Code Output Signal
B1 4-20mA
B3 0-10v
B4 0-5V
B5 1-5V
Code Process Connection
K1 2 inch clamp connection
K2 2.5 inch clamp connection
P Specify thread size
Code Electrical connections
C1 Hirschman joint
C2 Cable output
C3 Aviation connector
Code Structure Material
Diaphragm Interface Shell
M1 316L Stainless steel Stainless steel
M3 Tantalum customize customize
M4 Hastelloy C customize customize
Code Additional functions
G Gauge pressure (default)
A Absolute pressure
S Sealed gauge pressure
D1 Local display
Y2 Blue protective shell
T High temperature -XX℃


Product Specification

 

Item Specification
Measuring range Relative pressure: maximum 0 ~ 7MPa, minimum 0 ~ 5KPa, customized up to 100MPa
Absolute pressure: Maximum 0~60MPa; Minimum 0~20KPa
Negative relative pressure: -1KPa~-0.1MPa
Accuracy class ±0.5%F.S
Temperature effect Tk≤±0.02%FS/K
Stability Better than 0.1%FS/year
Location effect Mounting position does not affect zero point
Permissible temperature Medium temperature: -20~80℃, -40~200℃
Ambient temperature: -30~80℃
Storage temperature: -30~80℃
Protection class IP64, IP65
Adjustment range Zero adjustment range ±5%
Full scale adjustment range ±20%
Power supply 16~32VDC
Output signal 4~20mA DC (analog, two-wire system)
1~5V DC (analog, three-wire system)
Wiring lead-out method It can be drawn out from any outlet according to the needs. It is recommended to use a minimum of φ7.5 industrial cable as the lead for sealing. The lead-out connector is a general cable connector M12×1.5, and the end without the lead is sealed with an end cover
Pressure interface Stainless steel clamp type; thread M27×1.5, G1/2, G3/4, NPT1/2,